Hemocue 301 pdf merge

Pdf evaluation of the diagnostic accuracy and cost of different. The sensitivity, specificity, positive and negative predictive values for the hemocue 301 method were respectively 61. The calibration of the analyser has been changed 1. Pdf hemoglobin concentration and anemia diagnosis in venous. Page 1 page 2 page 3 page 4 components page 5 page 6 startup page 7 page 8 setup audio signal, time and date page 9 page 10 measuring capillary blood page 11 page 12 page page 14 page 15 page 16 page 17 page 18 measuring venous or arterial blood page 19 page 20 setup qc. Hemocue india setting the standard for accuracy in pointof. The 2018 nigeria dhs is the first survey to collect data on sickle cell disease. The analyzer and microcuvettes must be used together as a system. Hemocue hb 301 system the hemocue hb 301 system provides quick and easy access to labquality results in three seconds or less.

Optimized for anemia screening in primary care and blood donation settings, the hemocue hb 301 system is a simple and convenient solution. Hemocue a danaher company, develops, produces and markets medical diagnostic products for pointofcare testing within hematology and diabetes. The hemocue hb 301 system is for invitro diagnostic use only. Pdf attitudes and behaviours of greeks concerning blood. Hemocue hb 301 system maintenance instruction youtube. Making the order process easy, the kit contains all.

Methods we analysed population representative, crosssectional nutrition surveys from 20 to 2016 conducted by. Make sure the control is mixed properly and at room. Microcuvette hemocue hb 301 hemoglobin for hemocue hb 301 analyzer 50 microcuvettes per vial 10 l hemocue 111801. Microcuvette, for hemocue photometer hb 301, box200. With dedicated support and service as well as unmatched training and education based on over 30 years of experience, you can count on hemocue for the right solutions for all.

Hb 301 analyzer 121804us hb 301 microcuvettes 200box 111801 mean of icsh results, gdl hb 301 all test method results, gdl hemocue hb 301 vs icsh 10 5 0 15 20 30 0 5 10 15 20 25 30 25 y x hemocue has been a leader in pointofcare medical diagnostics for over 30 years. The fda has not approved this treatment regimen as a comprehensive unit. The procedural manual for the testing process was followed. Factory calibrated against the icsh reference method. Differences in performance of the pointofcare assays, compared to the reference assay, were more pronounced in the community based clinic. Forms occupational safety and health administration.

Hemocue hb 201 method and sample collection method iecbe. The hemocue hb 301 system provides quick, easy access to labquality results without compromising accuracy, even in demanding climates with high temperatures and humidity. Microcuvette,for hb 301box200 unicef supply catalogue. Hemocue hb 301 analyzer hemocue hb 301 microcuvettes 4 type aa batteries 1. It is optimized for use in primary care and blood donation settings in urban as well as in rural settings. To prepare the control sample, follow the steps below.

Pdf diagnostic accuracy of the hemocue hb 301, statsite. Specificity and positive predictive value of cuso 4 was higher than hemocue 83% and 80% to 70% and 59%. Eteindre lanalyseur et le rallumer apres 30 secondes. This manual provides the basic instructions for use as well as technical specifications. Technical support 40 empire drive lake forest, ca 92630. Supplied with instruction manual in english, french, spanish. The hemocue hb 301 system is designed for quantitative pointofcare whole blood hemoglobin determination in primary care using a specially designed analyzer, the hemocue hb 301 analyzer, and specially designed microcuvettes, the hemocue hb 301 microcuvettes. With the reference method, anaemia was present in 17. We assessed the diagnostic accuracy of the hemocue hb 301, statsite m hgb and urit12 pointofcare hemoglobin meters, compared to a central laboratory based reference assay, in a central laboratory and a community based clinic in durban, south africa. The lack of anaemia prevalence estimates among the displaced inhibit global planning for anaemia reduction. Jul, 2012 system cleaning instructional film for the hemocue hb 301 system. An evaluation of the hemocue for measuring haemoglobin in. The hemocue hb 301 system is for in vitro diagnostic use only. Hemocue hb 301 system optimized for anemia screening in primary care and blood donation settings the hemocue hb 301 system provides quick, easy access to labquality results without compromising accuracy, even in demanding climates with high temperatures and humidity.

Hemocue hb 201 microcuvettes are for in vitro diagnostic use only. The burden of anaemia among displaced women and children in. Microcuvette hb 301 hemoglobin 50 microcuvettes 1 bottle 50 cuvettes by hemocue. The hemocue hb 301 system provides quick and easy access to labquality results in three seconds or less. None of the proposed elements have specifically been approved by the fda for outpatient intravenous insulin treatment. Optimised for anemia screening in primary care and blood donation settings, the hemocue hb 301 system is a simple and convenient solution. Operating manual bedienungsanleitung manuel dutilisation. Introduction displaced persons have a unique risk for developing anaemia due to often limited diets, overcrowding, new infections and inadequate sanitation and hygiene. Take a new microcuvette and repeat the measurement.

Accurate poc anemia screening from the pioneers optimized for anemia screening in primary care and blood donation settings, the hemocue hb 301 system. They also have limited access to the osha form 301 or its equivalent. Apr 05, 2016 diagnostic accuracy of the hemocue hb 301, statsite mhgb and urit12 pointofcare hemoglobin meters in a central laboratory and a community based clinic in durban, south africa. Pdf the burden of anaemia among displaced women and. Capillary, venous or arterial whole blood may be used. Hemocue hb 301 system microcuvette information youtube. Ivd medical device directive the hemocue hb 201 microcuvettes comply with the ivd medical device directive 9879ec and carry the ce mark principles of the methodprocedure principle of the method. The hemocue learning solutions meet the needs of most practitioners, regardless of travel schedule, learning style or experience. Functioning of the hemocue machines photometer and. The controls are beyond their expiration dates or have been improperly stored 8. Check the expiration date and the storage conditions of the microcuvettes. Our multiple learning platforms make it easy for you to fit training into your busy schedule. Haemoglobin levels were measured using the hemocue hb 301 system gold standard.

Ideal for hemoglobin measurement in blood bank donation and public health settings. Optimized for anemia screening in primary care and blood donation settings, the hemocue hb 301. Pointofcare anemia screening hemocue hb 301 system. For further information regarding our products and services, please visit the hemocue. The robust hemocue hb 301 system is an accurate and effective tool for anemia screening also in demanding climate with high temperature and humidity. We compared haemoglobin values obtained by the hemocue system with those from the coulter counter splus iv in 366 pregnant women in urban jamaica, and found a highly significant correlation r 0. The hemocue hb 201 dm system consists of a portable, factory calibrated, dual wave, hand held photometer, and disposable microcuvettes containing dry reagents.

The burden of anaemia among displaced women and children. In vitro principle of the method principle of the procedure. The hemocue technique is based on an optical measuring microcuvette of a small. Proposed decision memo for outpatient intravenous insulin. Haemoglobin concentration was measured using a capillary blood sample from the fingertip and recorded in grams per decilitre gdl or grams per litre gl using the hemocue hb 301 analyser. Regular human insulin, which has long been used offlabel as an intravenous drip in the inpatient setting, especially intensive care units, acquired a. Dguv bgg 966 pdf bgg dguvg as a certified ipaf training centre, liftmanager is systematically developing the ipaf training with their three qualified trainers in.

The hemocue hb 201 analyzer is only to be used with hemocue hb 201 microcuvettes. Any printed copies are uncontrolled unless specified. Diagnostic efficacy of digital hemoglobinometer truehb, hemocue. Hemocue hb 301 system to learn more about the hemocue hb 301 system, please scan the qrcode with your smartphone or visit accurate poc anemia screening from the pioneers optimized for anemia screening in primary care and blood donation settings, the hemocue hb 301 system is a simple and convenient solution. The microcuvette is not a hemocue hb 301 microcuvette. Refer to the hemocue operators manual for complete instructions on how to analyze a control material. With dedicated support and service as well as unmatched training and education based on over 30 years of experience, you can count on hemocue for the right solutions for all your needs. Make sure that the cuvette holder is replaced properly. Not only does the unique cuvette technology enable lab accuracy in just three simple steps, but it reduces serious contamination risks.

The haemoglobin concentration is then displayed as a digital reading, in either gdl or mmoll in 1545 seconds. Factors affecting hemoglobin measurement request pdf. Technical support at 18004267256 for more detailed instruction. The hemocue haemoglobinometer has established a method for this, but it is considerably more expensive. Pdf the new hemocue system hb 301 r for the haemoglobin. Data pertaining to the reference test was merged with the main data after matching. Cw\point of care\hemoglobin this is a controlled document for cw use only. Diagnostic accuracy of the hemocue hb 301, statsite mhgb. Hemocue hb 201 microcuvettes are for in vitro diagnostic use in solid form to avoid dilutional effects.

The dhs program quality information to plan, monitor and. Pointofcare anemia screening hemocue hb 301 system kit. A strong correlation was shown with a pearsons coefficient of 0. Oct 09, 2015 system microcuvette training film for the hemocue hb 301 system. Only use hemocue hb 301 microcuvettes in the hemocue hb 301 analyzer. If refrigerated, place the bottles of control solution to be analyzed at room temperature 1525 c for 20 minutes prior to use.

1098 1058 476 789 199 1072 1416 856 6 868 1110 690 682 702 936 757 177 1115 961 988 631 176 106 1390 373 395 1100 702 679 169 252 988 851 139 1309 1078 1019 434 312 225 85 1216